Heat Bank Thermal Store System  
HBPP System D  
Everest combination unit  
Single Heat Exchanger (30 ltr/min)  
Indirect  
40mm Foam Insulation  
High duty primary coil  
S-Plan primary controls  
Sealed primary system  
12 litre Primary Expansion Vessel  
Fitted programmer  
Fitted Primary Pump, 6m head  
All fitted controls are wired  
Thermostatic Blending Valve 22mm  
28mm Primaries  
Backup Immersion Heater  
PCB Wiring Centre  
Primary Filling Loop  
Cased  


2   Plate Heat Exchanger
3   Heat Exchanger Pump
4   Flow Switch
7   Automatic Air Vent
8   Filling Vent
9   Feed to Ball Valve
10  Isolating Valve
11  Y-Pattern Strainer (supplied loose)
12  Overflow
13  Cold Feed / Expansion
14  Immersion Heater 3kW Incaloy with Stat
16  Cold Mains In, 22mm
17  Hot Mains Out, 22mm
18  Drain Cock
19  Flow From Boiler 28mm
21  Flow to Primary Coil
22  Return from Primary Coil
23  Flow to Heating 28mm
25  By-Pass Connection 15mm
29  Primary Coil Balancing Valve
26  Primary Pump UPS 15/60
30  Primary Expansion Vessel 12 litres
31  Primary Filling Point, with Check Valve
32  Pressure Relief Valve with Gauge 3 bar 1/2''
33  Programmer Danfoss CP715
35a Two Port Zone Valve - Hot Water 22mm
35b Two Port Zone Valve - Heating 28mm
38  Cylinder Thermostat
42  Wiring Centre

 

Unit ID

SC-130-3342-1SC-300-3342-1

Capacity

130300

Base Diameter

450500

Overall Diameter

530580

Height

11901900

Contents:
1. Introduction
2. General Requirements
3. Mains Water Supply
4. Connections:
5. Wiring
6. Filling
7. Commissioning
8. Fault Finding
9. Servicing
10. Spares
11. User Instructions